Morley / Addressable Audio Visual Devices / All
Trade-only SKU list for this range, ordered A-Z to support specification and replacement sourcing.
Alphabetical SKU list
- BGL-PC-I00 - Red Flash, Pure White Body, Clear Lens, c/w Isolator. Loop-powered EN54-23 C Category - Detector Base Strobe. EN54-23 certified. Coverage volume code: C-3-8.5
- BRH-PC-I00 - Body Colour - White Flash - Red Lens - Clear Isolator - Yes High Performance Detector Base Sounder Strobe. Loop-powered EN54-23 C Category - EN54-23 certified. Coverage volume code: C-3-15 (High) / C-3-11 (Low) / C O-1-4 (Legacy).
- BRS-PC-I00 - Red Flash, Pure White Body, Clear Lens, c/w Isolator. Loop-powered EN54-23 C Category - Standard Performance Detector Base Sounder Strobe. EN54-23 certified. Coverage volume code: C-3-8.5 (Standard) / O-1-3 (Legacy)
- BSO-PP-I00 - Pure White Body c/w Isolator. Base Sounder - Addressable loop powered base sounder, EN54-3 approved.
- BSO-PP-N00 - Pure White Body no Isolator. Base Sounder - Addressable loop powered base sounder, EN54-3 approved.
- DSS-PC-I00 - Red Flash, Pure White Body, Clear Lens c/w Isolator. Loop-powered EN54-23 Open Category Detector Base Sounder Strobe in pure white. Requires a B501AP base for fast and simple installation for System Sensor detectors and a choice of sound output levels and tones selectable from the device or panel
- DSS-PC-N00 - Red Flash, Pure White Body, Clear Lens, no Isolator. Loop-powered EN54-23 Open Category Detector Base Sounder Strobe in pure with white. Non-isolated version. Requires a B501AP base for fast and simple installation for System Sensor detectors and a choice of sound output levels and tones selectable from the device or panel
- PS340 - 10 X IP 21 SEAL(C 934) BRH/BRS/BGL
- WRA-PC-I00 - Body Colour - White Flash - Red Lens - Clear Isolator - Yes Wall Sounder VAD - Wall-mounted, addressable, loop-powered sounder, EN54-3 approved, with Visual Alarm Device (VAD), EN54-23 W & O class compliant. EN 54-23 COVERAGE STANDARD OUTPUT MODE: W-3.6-10.5, W-2.4-10.5 EN 54-23 COVERAGE HIGH OUTPUT MODE: W-4.2-11.5, W-2.4-11.5 EN 54-23 COVERAGE LEGACY MODE: O-2.4-3
- WRA-RC-I00 - Body Colour - Red Flash - Red Lens - Clear Isolator - Yes Wall Sounder VAD - Wall-mounted, addressable, loop-powered sounder, EN54-3 approved, with Visual Alarm Device (VAD), EN54-23 W & O class compliant. EN 54-23 COVERAGE STANDARD OUTPUT MODE: W-3.6-10.5, W-2.4-10.5 EN 54-23 COVERAGE HIGH OUTPUT MODE: W-4.2-11.5, W-2.4-11.5 EN 54-23 COVERAGE LEGACY MODE: O-2.4-3
- WRL-PC-I00 - Body Colour - White Flash - Red Lens - Clear Isolator - Yes Wall VAD - Wall-mounted, addressable, with Visual Alarm Device (VAD), EN54-23 W class compliant. EN 54-23 COVERAGE: W-3.6-10.5, W-2.4-10.5
- WRL-RC-I00 - Body Colour - Red Flash - Red Lens - Clear Isolator - Yes Wall VAD - Wall-mounted, addressable, with Visual Alarm Device (VAD), EN54-23 W class compliant. EN 54-23 COVERAGE: W-3.6-10.5, W-2.4-10.5
- WSO-PP-I00 - White, c/w isolator, Wall Sounder - Wall-mounted, addressable, loop-powered sounder, EN54-3 approved.
- WSO-PP-N00 - White, no Isolator. Wall Sounder - Wall-mounted, addressable, loop-powered sounder, EN54-3 approved, Not isolated
- WSO-PR-I00 - Red c/w Isolation. Wall Sounder - Wall-mounted, addressable, loop-powered sounder, EN54-3 approved.
- WSO-PR-N00 - Red, no Isolator. Wall Sounder - Wall-mounted, addressable, loop-powered sounder, EN54-3 approved.
- WSS-PC-N00 - Red Flash, Pure White Body, Clear Lens, non-Isolated. Wall Sounder Strobe - Wall-mounted, addressable, loop-powered sounder, EN54-3 approved, with Visual Alarm Device (VAD), EN54-23 O class compliant (W-1.9-1.9).
- WSS-PR-I00 - Red Flash, Pure White Body, Red Lens c/w Isolation. Wall Sounder VID - Wall-mounted, addressable, loop-powered sounder, EN54-3 approved, with visual indicating device (VID). This product is not approved to EN54-23 (Visual Alarm Device) and must not be used as a visual alarm device to provide a primary warning notification of fire
- WSS-PR-N00 - Red Flash, Pure White Body, Red Lens, no Isolator. Wall Sounder - Addressable loop powered base sounder, EN54-3 approved, with visual indicating device (VID). This product is not approved to EN54-23 (Visual Alarm Device) and must not be used as a visual alarm device to provide a primary warning notification of fire.
- WST-PC-N00 - Red Flash, Pure White Body, Clear Lens, non-Isolated. Wall VAD - Wall mounted, addressable loop powered EN54-23 O class compliant (W-1.68-1.68).
- WWA-PC-I00 - Body Colour - White Flash - White Lens - Clear Isolator - Yes Wall Sounder VAD - Wall-mounted, addressable, loop-powered sounder, EN54-3 approved, with Visual Alarm Device (VAD), EN54-23 W & O class compliant. EN 54-23 COVERAGE STANDARD OUTPUT MODE: W-3.8-9, W-2.4-9 EN 54-23 COVERAGE HIGH OUTPUT MODE: W-4-11.5, W-2.4-11.5 EN 54-23 COVERAGE LEGACY MODE: O-2.4-3
- WWA-RC-I00 - Body Colour - Red Flash - White Lens - Clear Isolator - Yes Wall Sounder VAD - Wall-mounted, addressable, loop-powered sounder, EN54-3 approved, with Visual Alarm Device (VAD), EN54-23 W & O class compliant. EN 54-23 COVERAGE STANDARD OUTPUT MODE: W-3.8-9, W-2.4-9 EN 54-23 COVERAGE HIGH OUTPUT MODE: W-4-11.5, W-2.4-11.5 EN 54-23 COVERAGE LEGACY MODE: O-2.4-3
- WWL-PC-I00 - Body Colour - White Flash - White Lens - Clear Isolator - Yes Wall VAD - Wall-mounted, addressable, with Visual Alarm Device (VAD), EN54-23 W class compliant. EN 54-23 COVERAGE: W-3.8-9, W-2.4-9
- WWL-RC-I00 - Body Colour - Red Flash - White Lens - Clear Isolator - Yes Wall VAD - Wall-mounted, addressable, with Visual Alarm Device (VAD), EN54-23 W class compliant. EN 54-23 COVERAGE: W-3.8-9, W-2.4-9
Trade support for Gent ranges
Need availability guidance or help identifying the right SKU? Our team can support sourcing for projects and maintenance.
Request a quote