- 020-773 - Routing Termination Unit 1 (RTU01). Use on the Fault Routing output on the 795-132 to allow full monitoring of the transmission path to transmission device. Allows compliance with EN54-2 OWR 8.9
- 714-001-111 - DXc1 Single loop panel (no zone LEDs) 230Vac, 2 sounder circuits. Supports Apollo, System Sensor and Hochiki protocols. 260 x 390 x 147mm (H x W x D).
- 714-001-221 - DXc2 2 Loop control panel (no zone LEDs) 230Vac, 2 sounder circuits. Supports Apollo, System Sensor and Hochiki protocols.391.5 x 390 x 147mm (H x W x D).
- 714-001-241 - DXc4 4 Loop control panel (no zone LEDs) 230Vac, 2 sounder circuits. Supports Apollo, System Sensor and Hochiki protocols.391.5 x 390 x 147mm (H x W x D).
- 795-083 - Keyswitch kit. Keyswitch and 2x keys to mount into DX series control panels. Used for Level 2 access, class change and control of functions
- 795-084 - Spare keys for 795-083 - Pack of 5
- 795-097 - DXc Software programming kit (SPK) supports System Sensor, Apollo and Hochiki protocols
- 795-099 - Kit DXc Network Card, In order to connect panels together to create a network a DXc Network card must be fitted to each panel
- 795-101 - DXc Extension Box Cover Blank For Extension Box
- 795-102 - 40 Zone LED Card, includes PCB, ribbon cable, zone number labels & fixings. Zone LED PCB is fitted to the lower half of the front door
- 795-103 - DXc Extension cover, comes with 80 zone LED card
- 795-104 - DXc replacement door for DXc control panels. The spare door fits all three variants of the panel, DXc1, DXc2 & DXc4 and is supplied complete with display PCB, facia label, ribbon cable and lock.
- 795-106 - DXc1 Spare Power supply unit (PSU) for 1 loop panel
- 795-107 - DXc2/4 Spare Power supply unit (PSU) 2/4 loop panel
- 795-108-001 - DXc replacement text inserts, pack includes all text inserts/slide-in labels including both blank and numbered labels for Zone LEDs. Pack also includes the User Reference Guide and the Quick Start Manual
- 795-109-001 - DXc 1 loop base card - Apollo, System Sensor and Hochiki protocols
- 795-110-001 - DXc 2 loop base card - Apollo, System Sensor and Hochiki protocols
- 795-110-002 - DXc 2 loop base card - Morley Protocol
- 795-111 - DXc 2 Loop Expansion Card for use with the DXc4 only
- 795-112 - Flush bezel kit for DXc1 (small enclosure)
- 795-113 - Flush bezel kit for DXc 2/4 (medium enclosure)
- 795-114 - Flush bezel kit for DXc 1 with the extension backbox fitted (small enclosure)
- 795-115 - Flush bezel kit for DXc 2/4 with the extension backbox fitted (medium enclosure)
- 795-116 - The custom key plate cover is supplied with a painted metal plate. The metal plate can be removed and drilled to accept key switches or indicators and labelled accordingly by the installer. The custom key plate cover can be used to replace the blank cover supplied with the DXc2/4 control panels or used with the extension backbox, part No. 795-121
- 795-118 - DXc key switch kit, Control panels can be fitted with an optional key switch kit fitted by removing the existing label and replacing with a new label supplied with the kit. The flying lead (fitted with a plug) pushes on to the two pins situated at the bottom of the main display PCB
- 795-120 - Rack Mount Bracket for DXc2/4
- 795-121 - DXc extension Box increases the enclosure size of a DXc1, DXc2, or DXc4 control panel to accommodate larger batteries, relays or other equipment by fitting the extension back box, 263 x 390 x 147 (H x W x D).This Extension Box is supplied without covers. Two covers must be used with the box. Any combination of the three listed below can be used: 795-101, 795-103, 795-116
- 795-122 - DXc RS232 Card allows the connection of a serial device to the panel such as BMS system or our Visuleyez product range
- 795-124 - 80 ZONE LED Card, includes PCB, ribbon cable, zone number labels & fixings. Zone LED PCB is fitted to the lower half of the front door
- 795-132 - For use with DXc1-M (714-001-214) & DXc2-M (714-001-224) only. I/O card for EN54-13 compliant sounder circuits, Fire Routing interface, Fault Routing interface and Fire Protection interface. Routing Termination units may be required depending on application. Allows compliance with EN54-2 OWR 7.9.1 and 7.9.2, OWR 7.10, OWR 8.9
- 797-090 - DXc Extension EN54-4 compliant PSU backbox increases the enclosure size of a DXc2, or DXc4 control panel to accommodate an additional pair of 17Ah batteries to provide increased system battery standby of up to 34Ah at 24V(depending o the batteries fitted in the panel) . This unit is supplied with the backbox, two cover blanks and an additional power supply unit (PSU). 263 x 390 x 147 (H x W x D)